Intellectual ability
Quality inspection and control
Inspection standard for ceramic packaging base

Suitable for factory inspection and quality control of various ceramic packaging bases

According to the standard

Group Standard T/CECA 49-2021 "Piezoelectric Device Ceramic Packaging Base for Frequency Control and Selection"

Test category

There are 7 inspection categories in total, and 12 inspection items cover all aspects of inspection such as appearance, size, and performance.

Standard state

The current is effectively updated regularly to ensure compliance with the latest industry requirements

Test categoryInspection itemTest methodsJudgment standardTest basis/standard clause
AppearanceAppearanceProduct inspection using a 10x microscopeAccording to "T/CECA49-2021 Ceramic Packaging Base for Piezoelectric Devices for Frequency Control and Selection"Group Standard T/CECA 49-2021 6.2 Appearance Standard
SizeExternal dimensionProduct size and tolerances comply with drawing requirementsPer the drawingAccording to signed and approved technical drawings
Coating performanceCoating thicknessTest using X-fluorescence thickness gaugePer the drawingPer the drawing
Baking resistancePlace the bottom of the ceramic base downward in an oven at a temperature of 350±5℃ for 5± 0.5 minutes, and cool in air at room temperatureObserve under a 10x microscope, the surface of the bottom pad coating shall not appear mottled, foaming, peeling, etc.Group Standard T/CECA 49-2021 6.3.2.2 Test Method
Deposit adhesionUse a test adhesive tape with an adhesive force greater than 1N/cm2 to adhere to the bottom pad of the ceramic packaging base for 10±1min, and then use a uniform force in the direction perpendicular to the bottom pad to peel the adhesive tape from the bottom pad.Under bright light, use a 10x microscope to observe the solder pads and adhesive tape at the bottom of the ceramic packaging base. No coating fell off.Group Standard T/CECA 49-2021 6.3.3.2 Test Method
Salt spray test5% concentration of sodium chloride, spray time: 48h, temperature: 33℃,The appearance shall not appear rust, blisters or discolorationGroup Standard T/CECA 49-2021 6.13.2 Test Method
Electrical characteristicsInsulation resistanceUse insulation resistance measuring instrument, test T=24±2℃, measure voltage:DC(100±10)V t=5sR≥1*10⁹ΩGroup Standard T/CECA 49-2021 6.4.2 Test Method
conduction performanceUse a multimeter or DC resistance meter to testPer the drawingGroup Standard T/CECA 49-2021 6.4.2 Test Method
Solderability ofSolder testSoldering temperature (260±5)℃, dipping time (5±0.5) sBottom pad penetration area ≥95%Group Standard T/CECA 49-2021 6.7.2 Test Method
Air tightnessSeal testFirst seal the tested enclosure at the vacuum joint, then vacuum the enclosure cavity to 10Pa, and then use a spray gun to expose the exterior of the enclosure to a helium pressure of 236kPa.Standard leakage rate ≤9*10 ³ (Pa.m³/s)Group Standard T/CECA 49-2021 6.7.2 Test Method
Cover airtightness testUse a roller welding machine to air-seal BASE and conduct helium leakage detectionStandard leakage rate ≤9*10 ³ (Pa.m³/s)Group Standard T/CECA 49-2021 6.7.2 Test Method
Exit strengthPad tensionUse a copper wire with a diameter of 0.13mm to bond it to the metal pad, use a tension gauge to apply a tensile force to 1.47N in the direction perpendicular to the plane of the pad, and hold it for (10±1) sThe pads are not allowed to fall off, delaminate, crack or damageGroup Standard T/CECA 49-2021 6.11.2 Test Method